Types Z412, Z4124
The listed energy sources are used to power the readers of the system BIS®. They can be used in a number of applications that require a constant supply of electricity.
The back-up energy source type Z412 requires voltage 230V~/50Hz, the output voltage is 15.2V/5A, The output voltage is backed up by a 12V/7Ah storage battery, which is constantly recharged when the device is in operation. The battery storage is prevented from being completely discharged by a protective circuit that cuts the power off when the battery is below 10.7V. The sources are (momentarily) protected by an electrical fuse from a short circuit.
Should there be a need to extend the back-up time, we provide energy source Z4124, whose output voltage is backed up by four storage batteries 12V/7AH that are constantly recharged.
Energy source Z412:
Technical parameters of the power source Z412
Properties | Technical value |
---|---|
Power supply voltage: | 230V~/50 Hz |
Power consuption | Up 75VA |
IP Protection class: | IP 56 |
Output voltage: | 15,2V/5A ( power supply voltage 230V~/50Hz) |
Backup: | 12V/7Ah (not included as standard) |
Time backup (per a battery) | for 3 pcs of scanning unit – circa 1h 45min for 2 pcs of scanning unit – circa 3h |
Overvoltage protection: | 17,25 – 20,25V |
Overcurrent protection: | >110% |
Dimensions: | 240 x 160 x 90 mm |
Operating temperature: | -25°C – +55°C |
Back-up energy sources Z4124 with 4 batteries
Technical parameters of the power source Z4124
Properties | Technical value |
---|---|
Power supply voltage: | 230V~/50 Hz |
Power consuption | Up 75VA |
IP Protection class: | IP 56 |
Output voltage: | 15,2V/5A ( power supply voltage 230V~/50Hz) |
Backup: | 12V/7Ah, 4 pcs (not included as standard) |
Overvoltage protection: | 17,25 – 20,25V |
Overcurrent protection: | >110% |
Dimensions: | 395 x 315 x 130 mm |
Operating temperature: | -25°C – +55°C |
Power supply TL-POE200
Device TL-POE200B is used to power attendance readers HT200x and EP400x via Ethernet within 100 metres. Data and powering are divided into two cables. The output voltage can be regulated to 12.9 and 5V. This kind of powering is suitable only for units equipped with an internal MTCP converter.
Technical parameters:
Properties | Properties |
---|---|
Standards and Protocols: | IEEE 802.3, 802.3u CSMA / CD, TCP / IP |
Ports TL-POE200B: | 1x 10/100M RJ45 LAN 1x 10/100M RJ45 PoE |
Power supply: | Input: 48 V, 0,5 A PSU Output: 12/9/5 VDC |
Environment: | Operating temperature:0 °C ~ 40 °C Operating humidity: 10% ~ 90%, non condensing |
Others: | LED power indicator |
Dimensions: | 81 x 52 x 24 mm |
Power pack Z12
Selected types of scanners can be powered by an energy source that is not backed-up (a power pack). This solution is suitable in particular for autonomous readers SU104*, B104*.
Technical parameters:
Properties | Properties |
---|---|
Power supply voltage: | 230V~/50 Hz |
Power consuption: | 6 VA (at maximum load) |
IP Protection class: | IP 65 |
Output voltage: | 12V=/500mA |